Extension Kit for Systems with 2 collector fields or 2 tanks
The circulation unit is used on the primary circuit of solar heating systems to control the temperatures in the hot water storage. Module with pump, in combination with a FlowCon 2-line station is suitable for two solar storages or two collector fields.
For use in a closed loop design only.
Description
For use in a closed loop design only. The circulation unit is used on the primary circuit of solar heating systems to control the temperatures in the hot water storage. Module with pump, in combination with a FlowCon 2-line station is suitable for two solar storages or two collector fields.
The unit components enable:
• Medium Circulation with a specific pump
• Accurate Flow Rate control
• Filling / draining the circuit
• Measuring the return line temperature
• Shutting off the circuits and thermosyphoning
• Thermal Insulation
Technical Data
Max Pressure: 145 psi / 10 bar
Max Temperature: 266F / 130C, temp. 320F / 160C
Equipment:
• Check Valves: 200mm WC
• FlowMeter Range: 0.8-6 USgpm or 3-22 l/min
• Pressure Relief Valve: 87psi / 6bar, for solar thermal
• Pressure Gauge: 0-90psi 0-6bar, high temp. resistant
• temperature gauges: 32-320F / 0-160C, full metal
Dimensions:
• Connections: 3/4″ compression fitting
• Pipe-Center Distance: 100mm / 3.94″
• Width of Insulation: 172mm / 5″
• Height of Insulation: 320mm / 12.6″
• width (complete assembly): 513mm / 20.2″
• height (complete assembly): 460mm / 18.1″
Additional information
Weight | 15 lbs |
---|
Reviews